Step | Action | Yes | No |
---|---|---|---|
Important: A short will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open. | |||
1 | Did you perform the outside mirrors system check? | Go to Step 2 | Go to Symptoms |
2 |
Does the test light illuminate? | Go to Step 3 | Go to Step 6 |
3 | Inspect the outside mirror switch connector C1. Verify that the terminals are clean and tight. Are the terminals clean and tight? | Go to Step 5 | Go to Step 4 |
4 | Repair the outside mirror switch connector C1. Refer to Connector Repairs in Wiring Systems. Did you complete the repair? | Go to Symptoms | -- |
5 | Replace the outside mirror switch. Refer to Power Mirror Switch Replacement. Did you complete the repair? | Go to Symptoms | -- |
6 | Connect the test lamp between the outside mirror switch connector C1 terminal D and ground. Does the test light illuminate? | Go to Step 7 | Go to Step 8 |
7 | Repair an open in CKT 150 between the outside mirror switch connector C1 terminal A and G304. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair ? | Go to Symptoms | -- |
8 | Repair an open, high resistance, or short to ground in CKT 1040. Did you complete the repair? | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |