GM Service Manual Online
For 1990-2009 cars only

Object Number: 1584015  Size: MF

Callout

Component Name

Caution: Refer to Fastener Caution in the Preface section.

Fastener Tightening Specifications: Refer to Fastener Tightening Specifications.

Preliminary Procedure

  1. Remove the fuse labeled HVAC CTRL (BATT).
  2. Remove the air inlet assembly. Refer to Air Inlet Assembly Replacement.
  3. Disconnect the recirculation actuator electrical connector.

1

Screw, Recirculation Housing (Qty: 4)

Tighten
1.5 N·m (14 lb in)

2

Housing, Recirculation

3

Screw, Recirculation Actuator (Qty: 3)

Tighten
1.5 N·m (13 lb in)

4

Actuator, Recirculation

Procedure

    • Disconnect the actuator electrical connector.
    • Recalibrate the Actuator. Refer to Actuator Recalibration