Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Relay Switch B+ Circuit | 2 | 2 | -- | -- |
Rear Defogger Relay Control | B0283 02 | B0283 05 | B0283 05 | -- |
Relay Controlled Output Circuit | 2 | 2 | 3 | -- |
Rear Defogger Switch Signal | 2 | 2 | 2 | -- |
Defog Switch Ground | -- | 1,2 | 1,2 | -- |
Rear Window Defogger Grid Ground | -- | 2 | 2 | -- |
Relay Coil Ground Circuit | -- | 2 | 2 | -- |
1. HVAC Defogger Indicator Inoperative 2. Rear Defogger Inoperative 3. Rear Defogger Always ON |
Battery positive voltage is supplied through the RDFG fuse, in the underhood fuse block, to the RDFG relay switched input. Ground for the RDFG relay is provided by G101. The BCM supplies 12 volts on the rear window defogger switch signal circuit to the HVAC control assembly. When you depress the defog switch, the rear window defogger switch pulls the signal circuit low. The BCM interprets as a request for the rear window defogger system. The BCM enables the rear window defogger system by supplying voltage to the RDFG relay coil. The relay coil supply voltage is also spliced off internally in the BCM to the supply voltage circuit of the defogger indicator. The RDFG relay is energized and the defogger indicator is illuminated. With the relay energized, battery positive voltage is allowed from the relay switched input through the switch contacts and out the relay switched output to the rear window defogger grid. Ground for the rear window defogger grid is provided by G403.
When you start the engine and press the defog switch for the first time, the defogger cycle lasts for 15 minutes. Further operation results in 7.5 minute defogger cycles. The rear defogger feature will not time out if vehicle speed is above 80 km/h (50 mph). The defogger cycle resets to 15 minutes when you cycle the ignition to the OFF position and then to the ON position.
Stationary Windows Connector End Views
Rear Window Defogger Description and Operation
⇒ | If the reading does not change between the commanded states, refer to HVAC Defog Switch Malfunction. |
⇒ | If the rear window defogger does not turn ON and OFF when changing between the commanded states, refer to Rear Defogger Malfunction. |
⇒ | If the Defogger Indicator does not illuminate or continuously illuminates, refer to Rear Defogger Indicator Malfunction. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal A8 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the relay coil ground circuit for an open/high resistance. |
⇒ | If the test lamp illuminates, test the relay controlled output circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the relay switch B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the switch side circuit fuse is open, test the relay controlled output circuit for a short to ground. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the Rear Window Defogger Grid does not activate, test the relay controlled output circuit for an open/high resistance. If the circuit tests normal, test or replace the Rear Window Defogger Grid. |
⇒ | If the test lamp is always ON, test the rear defogger control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the rear defogger control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, replace the HVAC control assembly. |
⇒ | If greater than the specified range, replace the HVAC control assembly |
⇒ | If the Defog Indicator does not illuminate, replace the HVAC Control Assembly. |
⇒ | If the resistance is not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for BCM replacement, setup and programming.