Notice: Do NOT remove the three bolts which hold the pump together.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
• | Tighten the M6 X 1.0 X 20 bolt to 8 N·m (70 lb in). |
• | Tighten the M6 X 1.0 X 85 bolt to 12 N·m (106 lb in). |
• | Tighten the M6 X 1.0 X 95 bolt to 16 N·m (11 lb ft). |
Important: It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.