DEFINITION: Noise originating from the HVAC module.

1

Were you sent here from Symptoms or another diagnostic table?

Go to Step 2

Go to Symptoms - HVAC Systems - Manual

2

  1. Start the engine.
  2. Cycle through all of the following:
  3. • Blower motor speeds
    • HVAC modes
    • Temperature control settings
  4. Determine the type of noise:
  5. • Scrape, pop
    • Tick/click, chirp or groaning
    • Air rush/whistle

Is a scrape or pop noise evident when selecting modes or temperature settings?

Go to Step 6

Go to Step 3

3

Is a tick/click, chirping, groaning or scraping noise present, but decreases as blower motor speed is decreased?

Go to Step 6

Go to Step 4

4

Is an air rush/whistle noise evident in all modes but not all temperature settings?

Go to Step 6

Go to Step 5

5

Is an air rush/whistle noise evident only in defrost or floor mode?

Go to Step 6

Go to Step 1

6

Remove the I/P trim pad. Refer to Instrument Panel Trim Pad Replacement in Instrument Panel, Gages, and Console.

Is the action complete?

Go to Step 7

--

7

  1. Inspect the mode valve assembly for proper operation.
  2. Inspect the ducts for obstructions or foreign materials.

Were any of these conditions found?

Go to Step 10

Go to Step 8

8

Inspect the mode valve assembly, temperature door and seals for warping or cracking.

Are the doors in normal condition?

Go to Step 11

Go to Step 9

9

Replace the appropriate door, mode valve assembly or seals.

Is the repair complete?

Go to Step 11

--

10

Remove any obstructions or foreign material found.

Is the action complete?

Go to Step 11

--

11

Install the I/P trim pad. Refer to Instrument Panel Trim Pad Replacement in Instrument Panel, Gages, and Console.

Is the action complete?

Go to Step 12

--

12

Operate the system to verify the repair.

Did you find and correct the condition?

System OK

Go to Step 2