Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Is the blower motor OFF? | Go to Step 3 | Go to Blower Motor Always On |
3 | Place the blower motor switch in each speed position. Does the blower motor operate in each speed position? | Go to Step 4 | Go to Blower Motor Inoperative |
4 | Does the blower motor operate at the desired speeds? | Go to Step 5 | Go to Blower Motor Malfunction |
5 |
Does the scan tool display any DTCs? | Go to Step 6 | |
6 | Place the mode switch in each mode position. Does the air flow from the correct air distribution outlets in each selected mode position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 7 |
7 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 8 |
8 | Inspect and the air distribution system for the following conditions:
Did you find and correct the condition? | Go to Step 10 | Go to Step 9 |
9 |
Important: Perform the recalibration procedure for the HVAC control module. Replace the HVAC control module. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |