Removal Procedure
- Remove the right side I/P insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages
and Console.
- Disconnect the electrical connector from
the blower control module.
- Remove the two heat stakes from the blower control module using a small
chisel.
- Remove the blower control module.
Installation Procedure
- Install the blower control module.
Notice: Refer to Fastener Notice in the Preface section.
- Install the two new screws in the pre drilled holes to the side of the heat
stakes in the blower control module and the HVAC module assembly.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the electrical connector to the
blower control module.
- Install the right side I/P insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages
and Console.