The knock sensor (KS) produces an AC voltage at all engine speeds and loads. The power control module (PCM) then adjusts the spark timing based on the amplitude and frequency of the KS signal. The PCM uses the KS signal to calculate the average voltage. Then, the PCM assigns a voltage value. The PCM checks the KS and the related wiring by comparing the actual knock signal to the assigned voltage range. A normal KS signal should stay outside the assigned voltage range. This DTC will set if the PCM malfunctions in a manner that will not allow proper diagnosis of the KS system and related wiring.
• | DTCs P0101, P0102, P0103, P0107, P0108, P0117, P0118, P0121, P0122, P0123, P0125, P0336, P1114, P1115, P1121, P1122, or P1336 are not set. |
• | The engine speed is between 1,000-5,000 RPM. |
• | The throttle angle is more than 15 percent . |
• | The engine load is more than 40 percent . |
• | The engine coolant temperature is more than 60°C (153°F). |
• | The maximum spark retard is less than 15 degrees. |
• | The system voltage is more than 9 volts. |
• | The engine run time is more than 30 seconds. |
• | The PCM detects a malfunction in the integrated knock sensor diagnostic circuitry which will not allow proper diagnosis of the knock sensor circuit. |
• | Above conditions for at least 1 second. |
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
If the condition is intermittent, refer to Lack of Power, Sluggishness, or Sponginess .
Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Diagnostic System Check-Engine Controls? | Go to Step 2 | |
2 |
Does the DTC fail this ignition? | Go to Step 3 | Go to Intermittent Conditions |
3 | Replace the PCM. Refer to Powertrain Control Module Replacement . Did you complete the replacement? | Go to Step 4 | -- |
4 |
Did the DTC Run and Pass? | Go to Step 5 | Go to Step 2 |
5 | With a scan tool, observe the stored information, Capture Info. Does the scan tool display any DTCs that you have not diagnosed? | System OK |