Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 | Open the IP compartment. Does the lamp turn ON? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 5 |
4 | Connect a test lamp between the courtesy lamps supply voltage circuit and the ground circuit of the IP compartment lamp. Does the test lamp illuminate? | Go to Step 7 | Go to Step 6 |
5 | Repair the open in the courtesy lamps supply voltage circuit of the IP compartment lamp. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 8 | -- |
6 | Repair the open in the ground circuit of the IP compartment lamp. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 8 | -- |
7 | Replace the IP compartment lamp switch. Refer to Instrument Panel Compartment Lamp Replacement . Did you complete the replacement? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |