Removal Procedure
- Remove the right instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gauges and Console.
- Remove the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gauges and Console.
- Remove the HVAC control vacuum valve. Refer to
HVAC Control Vacuum Valve Replacement
.
- Disconnect the vacuum line from the recirculation actuator.
- Lift to release the recirculation actuator retaining tab and slide
off mounting bracket.
- Disconnect the vacuum actuator plunger
rod from the recirculation lever and remove the recirculation actuator.
Installation Procedure
- Connect the recirculation actuator plunger
rod to the recirculation door, then extend the plunger.
Important: During installation, ensure that the recirculation actuator retaining
tab is positioned above the mating base on the HVAC control module case.
- Push the vacuum actuator toward the HVAC control module case to secure
the retaining tab.
Important: Check that the vacuum actuator pushrod is not binding on the recirculation
lever.
- Connect the vacuum harness connector to the recirculation actuator.
- Install the HVAC control vacuum valve. Refer to
HVAC Control Vacuum Valve Replacement
.
- Install the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gauges and Console.
- Install the right instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gauges and Console.