Removal Procedure
- Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
in Engine Controls-3.1L or
Air Cleaner Assembly Replacement
in Engine Controls-3.8L.
- Disconnect the electrical connector from the A/C refrigerant pressure
sensor.
- Remove the refrigerant
pressure sensor from the liquid line.
Installation Procedure
- Lubricate a new O-ring seal with mineral base 525 viscosity
refrigerant oil.
- Install the new O-ring seal.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the refrigerant
pressure sensor to the liquid line.
Tighten
Tighten the refrigerant pressure sensor to 4.7 N·m (41 lb in).
- Connect the electrical connector to the A/C refrigerant pressure
sensor.
- Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
in Engine Controls-3.1L or
Air Cleaner Assembly Replacement
in Engine Controls-3.8L
.