When the ignition is turned ON, the powertrain control module (PCM) will turn ON the in-tank fuel pump. The in-tank fuel pump will remain ON as long as the engine is cranking or running and the PCM is receiving ignition reference pulses. If there are no ignition reference pulses, the PCM will turn the in-tank fuel pump OFF 2 seconds after the ignition is turned ON or 2 seconds after the engine stops running.
The in-tank fuel pump is an electric pump attached to the fuel sender assembly. The fuel pump is designed to provide fuel at a pressure above the pressure needed by the fuel injectors. A fuel pressure regulator, attached to the fuel rail, keeps the fuel available to the fuel injectors at a regulated pressure. Unused fuel is returned to the fuel tank by a separate fuel return pipe.
The numbers below refer to the step numbers on the diagnostic table.
This step verifies that the fuel pump is operating.
This step tests for an internal fuel leak. If the fuel pressure drops during this test, then an internal loss of pressure is indicated.
This step tests the fuel pressure regulator. The fuel pressure regulator is controlled by engine vacuum. With engine vacuum applied, the pressure should drop the specified value.
This step inspects the fuel pressure regulator for a fuel leak from the vacuum port. If fuel leaks from the fuel pressure regulator while the fuel pump is commanded ON, replace the fuel pressure regulator.
This step tests for a loss of fuel pressure between the fuel feed pipe shut off adapter and the fuel pump.
This step tests for a leaking fuel injector, or fuel pressure regulator. If the fuel pressure remains constant during this test, the fuel injectors are not leaking fuel.
This step tests for a restricted fuel return pipe. If the fuel pressure is within the specified values, a restriction in the fuel return pipe is indicated.
This step determines if the fuel pressure regulator, or the fuel pump, is the cause of the low fuel pressure. If the pressure rises above the specified value, the fuel pump is OK.
This step verifies that a circuit condition is not the cause of a fuel pressure concern. Inspect all fuel pump electrical circuits thoroughly.
Step | Action | Values | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference:
| ||||||||||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |||||||||
Important: Inspect the fuel system for damage, or external leaks, before proceeding with this diagnostic.
Does the fuel pump operate? | -- | Go to Step 3 | ||||||||||
3 |
Important: Verify there is adequate fuel in the fuel tank before proceeding with this diagnostic.
Important:
Is the fuel pressure within the specified range? | 364-405 kPa (53-59 psi) VIN K 336-375 kPa (48-54 psi) VIN 1 | Go to Step 4 | Go to Step 12 | ||||||||
Important: The fuel pressure may vary slightly when the fuel pump stops running. After the fuel pump stops running, the fuel pressure should stabilize and remain constant. Monitor the fuel pressure gauge for 1 minute. Does the fuel pressure drop more than the specified value? | 34 kPa (5 psi) | Go to Step 9 | Go to Step 5 | |||||||||
5 |
Does the fuel pressure drop more than the second specified value? | 69 kPa (10 psi) 14 kPa (2 psi) | Go to Step 24 | Go to Step 6 | ||||||||
Does the fuel pressure drop the specified value when the engine is started? | 21-69 kPa (3-10 psi) | Go to Step 7 | Go to Step 8 | |||||||||
7 |
Do any of the scan tool parameters indicate a lean condition? | -- | Go to Step 17 | |||||||||
8 |
Does the fuel pressure drop the specified value when the vacuum is applied? | 21-69 kPa (3-10 psi) | Go to Step 21 | Go to Step 23 | ||||||||
Is the fuel pressure regulator leaking fuel? | -- | Go to Step 23 | Go to Step 10 | |||||||||
Does the fuel pressure remain constant? | -- | Go to Step 19 | Go to Step 11 | |||||||||
Does the fuel pressure remain constant? | -- | Go to Step 23 | Go to Step 20 | |||||||||
12 | Is the fuel pressure above the specified value? | 405 kPa (59 psi) VIN K 375 kPa (54 psi) VIN 1 | Go to Step 14 | Go to Step 13 | ||||||||
13 | Is the fuel pressure above the specified value? | 0 kPa (0 psi) | Go to Step 16 | Go to Step 17 | ||||||||
Is the fuel pressure within the specified range? | 364-405 kPa (53-59 psi) VIN K 336-375 kPa (48-54 psi) VIN 1 | Go to Step 22 | Go to Step 15 | |||||||||
15 | Inspect the fuel return pipe and the fuel rail outlet passage for a restriction. Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 23 | ||||||||
Notice: DO NOT allow the fuel pressure to exceed 517 kPa (75 psi). Excessive pressure may damage the fuel system. Does the fuel pressure rise above the specified value? | 405 kPa (59 psi) VIN K 375 kPa (54 psi) VIN 1 | Go to Step 23 | Go to Step 17 | |||||||||
17 | Inspect the following for a restriction:
Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 18 | ||||||||
Inspect the harness connectors and ground circuits of the fuel pump for poor connections. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 19 | |||||||||
19 |
Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 24 | ||||||||
20 |
Did you complete the replacement? | -- | Go to Step 25 | -- | ||||||||
21 | Repair the vacuum source to the fuel pressure regulator. Did you complete the repair? | -- | Go to Step 25 | -- | ||||||||
22 | Locate and repair the restricted fuel return line. Did you complete the repair? | -- | Go to Step 25 | -- | ||||||||
23 |
Important: Inspect for a missing or damaged fuel pressure regulator O-ring seal before replacing the fuel pressure regulator. Replace the fuel pressure regulator. Refer to Fuel Pressure Regulator Replacement . Did you complete the replacement? | -- | Go to Step 25 | -- | ||||||||
24 | Replace the fuel pump. Refer to Fuel Sender Assembly Replacement . Did you complete the replacement? | -- | Go to Step 25 | -- | ||||||||
25 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |