Removal Procedure
- Remove the instrument
panel (IPC) cluster trim plate. Refer to
Instrument Cluster Trim Panel Replacement
.
- Grind the material from the heat stakes at the base of the air
outlet deflector housing.
- Remove the air outlet deflector housing from the IPC trim plate.
- Using a small flat-bladed tool, disconnect the sides of the air
outlet deflector housing.
- Open the air outlet deflector housing in order to expose the air
outlet deflectors.
- Remove the air outlet deflectors from the housing by pressing
out from the front to the rear.
Installation Procedure
- Install the air outlet
deflectors to the housing by pressing in from the rear to the front.
- Connect the sides of the air outlet deflector housing by pressing
together until fully seated.
- Position the air outlet deflector housing to the remaining unused
heat stakes.
Important: If no unused heat stakes are available use LOCTITE® Black Max P/N
38050, or equivalent and Perma-Bond® accelerator P/N QFF16, or equivalent
on the heat stakes.
- Melt the new heat stakes tabs using a soldering iron with a wide tip.
- Inspect the air outlet deflectors for proper operation.
- Install the IPC trim plate. Refer to
Instrument Cluster Trim Panel Replacement
.