Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the cigar lighter and auxiliary outlet operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Verify that the cigar lighter is inoperative. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Does the new cigar lighter pop out to the edge of the cigar lighter housing and is the filament hot? | -- | Go to Step 4 | Go to Step 5 |
4 | Replace the cigarette lighter.
| -- | Go to Step 10 | -- |
5 | Inspect the CIG LTR fuse in the Fuse block for an open Is the fuse open? | -- | Go to Step 6 | Go to Step 7 |
6 | Use a test lamp to test for a short to ground on the cigar lighter feed circuit . Refer to Circuit Testing and Wiring Repairs . Did you locate and correct a short to ground on the circuit? | -- | Go to Step 10 | Go to Step 8 |
7 | Use a test lamp in order to probe between B+ and the cigar lighter ground circuit to test for an open or a loose connection. Refer to Circuit Testing and Wiring Repairs . Did you locate and correct an open or a loose connection in the cigar lighter ground circuit? | -- | Go to Step 10 | -- |
8 | Test for an open in the cigar lighter feed circuit. Refer to Circuit Testing and Wiring Repairs . Did you find and correct an open in the cigar lighter feed circuit? | -- | Go to Step 10 | Go to Step 9 |
9 | Replace the cigarette lighter housing.
Is the repair complete? | -- | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Symptoms |