Temperature Actuator Replacement LH
Removal Procedure
- Remove the left instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel,
Gauges and Console.
- Remove the knee bolster. Refer to
Knee Bolster Replacement
in Instrument Panel, Gauges and Console.
- Disconnect the electrical
connector from the temperature actuator.
- Remove the HVAC Con (HVAC Control) MiniFuse #27 from the IP electrical
center.
- Remove the mounting bolts from the temperature actuator.
- Remove the temperature
actuator.
Installation Procedure
- Position the temperature
actuator, then align the slots in the electric actuator driver to the flats
on the temperature valve shaft.
- Slide the electric actuator driver onto the shaft, while aligning
the actuator locating hole to the forward alignment pin on the HVAC module
case. The actuator driver should completely seat onto the temperature valve
shaft and the mounting holes should be flush with the mounting bosses on the
HVAC module case.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the mounting
bolts to the temperature actuator.
Tighten
Tighten the temperature actuator bolts to 1.5 N·m (13 lb in).
- Connect the electrical
connector to the temperature valve electric actuator.
- Install the knee bolster. Refer to
Knee Bolster Replacement
in Instrument Panel, Gauges and Console.
- Install the left instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel,
Gauges and Console.
- Install the HVAC Con (HVAC Control) MiniFuse #27 from the IP electrical
center.
Temperature Actuator Replacement RH
Removal Procedure
- Remove the right instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel,
Gauges and Console.
- Remove the instrument panel compartment. Refer to
Instrument Cluster Trim Panel Replacement
in Instrument Panel, Gauges
and Console.
- Disconnect the electrical
connector from the temperature actuator.
- Remove the HVAC Con (HVAC Control) MiniFuse #27 from the IP electrical
center.
- Remove the bolts retaining
the temperature actuator.
- Remove the temperature actuator.
Installation Procedure
- Position the temperature
actuator, then align the slots in the electric actuator driver to the flats
on the temperature valve shaft.
- Slide the temperature actuator driver onto the shaft, while aligning
the actuator locating holes to the forward alignment pin on the HVAC module
case. The actuator driver should completely seat onto the temperature valve
shaft and the mounting holes should be flush with the mounting bosses on the
HVAC module case.
- Install the retaining bolts.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the bolts to the temperature actuator.
Tighten
Tighten the temperature actuator bolts to 1.5 N·m (13 lb in).
- Connect the electrical
connector to the temperature actuator.
- Install the instrument panel compartment. Refer to
Instrument Cluster Trim Panel Replacement
in Instrument
Panel, Gauges and Console.
- Install the right instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel,
Gauges and Console.
- Install the HVAC Con (HVAC Control) MiniFuse #27 from the IP electrical
center.