Removal Procedure
- Remove the cross vehicle beam. Refer to
Instrument Panel Tie Bar Replacement
in Instrument Panel,
Gauges and Console.
- Disconnect the vacuum lines from the defroster vacuum actuator.
- Rotate the defroster valve
lever fully rearward (counterclockwise), then carefully insert a screw driver
between the bottom of the defrost valve lever and the protruding
wall of the HVAC module case below the valve lever in order to keep
the valve lever in place.
- Lift to release the defroster vacuum actuator retaining tab.
- Carefully rotate the defroster vacuum actuator upward and forward
to remove from the HVAC module case.
- Disconnect the vacuum
actuator pushrod from the defrost valve lever and remove the vacuum actuator.
Installation Procedure
- Connect the vacuum actuator
pushrod to the defrost valve lever.
- Carefully rotate rearward
and downward to align actuator slots with HVAC module case and push the vacuum
actuator toward the HVAC module to secure the retaining tab.
- Connect the vacuum lines to the defroster vacuum actuator.
- Install the cross vehicle beam. Refer to
Instrument Panel Tie Bar Replacement
in Instrument Panel,
Gauges and Console.