Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Inspect the fuse block for an open in the HVAC HI fuse. Is the HVAC HI fuse open? | -- | Go to Step 2 | Go to Step 5 |
2 |
Does the test lamp light ? | -- | Go to Step 4 | Go to Step 3 |
3 | Locate and repair a short to ground in CKT 40 (ORN). Is the repair complete? | -- | Go to Step 9 | -- |
4 |
Does the test lamp light ? | -- | Go to Step 5 | Go to Step 6 |
5 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the repair complete? | -- | Go to Step 9 | -- |
6 |
Is there an open or short to ground in CKT 52 (ORN)? | -- | Go to Step 7 | Go to Step 8 |
7 | Locate and repair the open or the short to ground in CKT 52 (ORN). Is the repair complete? | -- | Go to Step 9 | -- |
8 | Replace the heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete? | -- | Go to Step 9 | -- |
9 | Verify that the system operates properly. Does the system operate properly? | -- | System OK | Go to Symptoms |