The powertrain control module (PCM) monitors the high side refrigerant pressure via an A/C refrigerant pressure sensor. The A/C refrigerant pressure sensor is a 3 wire piezoelectric pressure transducer. A 5-volt reference, low reference, and signal circuits enable the sensor to operate. The A/C pressure signal can be between 0-5 volts. When the A/C refrigerant pressure is low, the signal value is near 0 volts. When the A/C refrigerant pressure is high, the signal value is near 5 volts.
This diagnostic procedure supports the following DTC:
DTC P0530 Air Conditioning (A/C) Refrigerant Pressure Sensor Circuit
• | The PCM detects an A/C request. |
• | The PCM detects the A/C refrigerant pressure signal circuit is less than 5 counts (0.09 volt) or more than 250 counts (4.90 volt). |
Any of the conditions for running the DTC are met for 20 seconds.
• | The PCM will not illuminate the malfunction indicator lamp (MIL). |
• | The PCM stores the failure records. |
• | The A/C compressor clutch is disabled. |
• | The DTC will become history if the PCM no longer detects a failure. |
• | The history DTC will clear after 40 fault-free ignition cycles. |
• | The DTC can be cleared with a scan tool. |
For an intermittent, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table.
Tests for the proper operation of the circuit in the low voltage range.
Tests for the proper operation of the circuit in the high voltage range. If the fuse in the jumper opens when you perform this test, the signal circuit is shorted to ground.
Tests for a short to voltage in the 5-volt reference circuit.
Tests for a high resistance or an open in the low reference circuit.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
2 |
Important:: The ambient air temperature must be above 3°C (38°F).
Does the A/C compressor operate? | -- | Go to Step 3 | |
3 |
Important: This step must be performed in an area with an ambient temperature that is greater than 0°C (32°F).
Does the scan tool indicate that the A/C High Side Pressure parameter is within the specified range? | 0.2-3.76 V | Go to Diagnostic Aids | Go to Step 4 |
Does the scan tool indicate that the A/C High Side Pressure parameter is less than the specified value? | 0.2 V | Go to Step 5 | Go to Step 11 | |
Does the scan tool indicate that the A/C High Side Pressure parameter is greater than the specified value? | 3.76 V | Go to Step 6 | Go to Step 9 | |
Does the voltage measure less than the specified value? | 5.1 V | Go to Step 7 | Go to Step 8 | |
Does the resistance measure less than the specified value? | 5 ohms | Go to Step 13 | Go to Step 12 | |
8 | Test the 5-volt reference circuit of the A/C refrigerant pressure sensor for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 14 |
9 | Test the 5-volt reference circuit of the A/C refrigerant pressure sensor for a short to ground, a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 10 |
10 | Test the signal circuit of the A/C refrigerant pressure sensor for a short to ground a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 14 |
11 | Test the signal circuit of the A/C refrigerant pressure sensor for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 14 |
12 |
Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 14 |
13 | Inspect for poor connections at the harness connector of the A/C refrigerant pressure sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 15 |
14 | Inspect for poor connections at the harness connector of the powertrain control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 16 |
15 | Replace the A/C refrigerant pressure sensor. Refer to Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | -- | Go to Step 17 | -- |
16 | Replace the PCM. Refer to Control Module References in Computer/Integrating Systems for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 17 | -- |
17 |
Does the DTC reset? | -- | Go to Step 3 | System OK |