Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 | Inspect the instrument panel compartment lamp. Is the lamp filiment open? | Go to Step 9 | Go to Step 3 |
3 |
Does the testlamp light? | Go to Step 4 | Go to Step 6 |
4 | Use a testlamp connected to battery positive voltage in order to test for ground at terminal B of the instrument panel compartment lamp/switch connector. Does the testlamp light? | Go to Step 5 | Go to Step 8 |
5 | Inspect for poor connections at the instrument panel compartment lamp/switch connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | System OK | Go to Step 7 |
6 | Repair the open in CKT 1732 between the lamp/switch connector and the left IP junction block. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | System OK | -- |
7 | Replace the instrument panel compartment lamp/switch assembly. Refer to Instrument Panel Compartment Lamp Switch Replacement in Instrument Panel, Gauges and Console. Did you complete the repair? | System OK | -- |
8 | Repair the open in the ground CKT 250. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | System OK | -- |
9 | Replace the instrument panel compartment lamp bulb. Did you complete the replacement? | System OK | -- |