Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Disconnect the fog lamp switch. Did the fog lamps turn off? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the fog lamp switch. Refer to Fog Lamp Switch replacement Fog Lamp Switch Replacement . Is the repair complete? | -- | System OK | -- |
4 | Replace the fog lamp relay with a known good one. Did the fog lamps turn off? | -- | Go to Step 5 | Go to Step 6 |
5 | Replace the fog lamp relay. Refer to Fog Lamp Relay Replacement . Is the repair complete? | -- | System OK | -- |
6 | Remove the fog lamp relay. Check for continuity to ground at terminal 85 of the fog lamp relay receptical. Is ground present? | -- | Go to Step 7 | Go to Step 8 |
7 | Repair short to ground in the fog lamp switch output circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and repair the condition? | -- | System OK | -- |
8 | Repair the short to power in the fog lamp feed circuit. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | System OK | -- |