GM Service Manual Online
For 1990-2009 cars only

The SIR Scan Tool Data List contains all the restraint system related parameters that are available on the scan tool. The parameters in the list are arranged in alphabetical order. The column, "Data List," indicates the location of the parameter within the scan tool menu selections.

Use the SIR Scan Tool Data List as directed by a diagnostic table or in order to supplement the diagnostic procedures. Begin all of the diagnostic procedures with the SIR Diagnostic System Check. Use the SIR Scan Tool Data List after the following are determined:

    • There is no published DTC procedure nor published symptom procedure for the customer concern.
    • The DTC or symptom diagnostic procedure indicated by the diagnostic system check does not resolve the customer concern.

The Typical Data Values are obtained from a properly operating vehicle under the conditions specified in the first row of the Scan Tool Data List table. Comparison of the parameter values from the suspect vehicle with the Typical Data Values may reveal the source of the customer concern.

SIR Scan Tool Data List

Ignition ON/Engine OFF/Driver Seat Belt Buckled

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Air Bag Deployment Commanded

Normal Mode, SIR Data

On/Off

Off

Battery State

SIR Data

Okay/Not Okay

Okay

Battery Voltage

SIR Data

Volts

12 Volts

BCM Poll

SIR Data

Received/Not Received

Received

Check Light

SIR Data

On/Off

On

Driver Airbag Loop Capacitance

SIR Data

nF

400-540

Driver Frontal Loop

SIR Data

Enabled/Disabled

Enabled

Driver Loop Resistance

SIR Data

ohms

2

Driver Pretensioner Loop

SIR Data

Enabled/Disabled

Enabled

Driver Pretensioner Resistance

SIR Data

ohms

2

Driver Side Pretensioner Loop Capacitance

SIR Data

nF

400-540

DTC Status

Normal Mode

On/Off

Off

Module Type

Normal Mode

2-digit number

Varies

Passenger Airbag Loop Capacitance

SIR Data

nF

400-540

Passenger Frontal Loop

SIR Data

Enabled/Disabled

Enabled

Passenger Loop Resistance

SIR Data

ohms

2

Passenger Pretensioner Resistance

SIR Data

ohms

2

Passenger Pretensioner Loop

SIR Data

Enabled/Disabled

Enabled

Passenger Side Pretensioner Loop Capacitance

SIR Data

nF

400-540

SIR Lamp

Normal Mode, SIR Data

On/Off

Off

SIR Serial Communication Fault

SIR Data

Yes/No

Yes

Voltage Low -- Loop Energy Reserve

SIR Data

On/Off