Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the blower motor operate in any speed position? | Go to Blower Motor Malfunction | Go to Step 3 |
3 |
Does the test lamp illuminate in any speed position? | Go to Step 10 | Go to Step 4 |
4 | Test the blower motor supply voltage circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 5 |
5 | Test the blower motor control circuit for an open or high resistance between the blower motor and S255. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 6 |
6 |
Does the blower motor operate in any speed position? | Go to Step 11 | Go to Step 7 |
7 |
Did you find and correct the condition? | Go to Step 16 | Go to Step 8 |
8 | Test the blower inhibit relay coil and switch ground circuits for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 9 |
9 | Test the blower motor switch control circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 12 |
10 | Inspect for poor connections at the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 13 |
11 | Inspect for poor connections at the blower inhibit relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 14 |
12 | Inspect for poor connections at the blower switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 15 |
13 | Replace the blower motor. Refer to Blower Motor Replacement in Heating Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 16 | -- |
14 | Replace the blower inhibit relay. Refer to Relay Replacement in Wiring Systems. Did you complete the replacement? | Go to Step 16 | -- |
15 | Replace the blower switch. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | Go to Step 16 | -- |
16 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |