Removal Procedure
- Remove the HVAC unit. Refer to
HVAC Module Assembly Replacement
in Heating, Ventilation and Air Conditioning.
- Disconnect the vacuum line (4) from the actuator (5).
- Remove the clip (8), spacers (1) and actuator rod (7)
from the lever (2).
- Remove the actuator retaining screws (6).
- Remove the actuator from the HVAC unit (3).
Installation Procedure
- Install the actuator (5) to the HVAC
unit.
Notice: Refer to Fastener Notice in the Preface section.
- Secure the actuator with the retaining screws (6).
Tighten
Tighten the nuts to 4 N·m (35 lb in).
- Install the clip (8), spacers (1) and actuator rod (7)
to the lever (2).
- Connect the vacuum line (4) to the actuator.
- Install the HVAC unit. Refer to
HVAC Module Assembly Replacement
in Heating,
Ventilation and Air Conditioning.