Diagnostic Instructions
Circuit/System Description
The instrument panel cluster (IPC) generates the audible warning through an acoustic chime generator in the IPC. The IPC receives audible warning requests via the serial data circuit from the body control module (BCM).
Reference Information
Schematic Reference
Connector End View Reference
Electrical Information Reference
Scan Tool Reference
Scan Tool Data List
for scan tool information
Circuit/System Testing
Important: Before performing this diagnostics, make sure no indicators are illuminated after the IPC performs a lamp test. If any indicators are illuminated after the bulb test, perform the indicator diagnostics before this diagnostics.
- Ignition ON, headlamp switch OFF, verify the scan tool Headlamp Switch parameter is Inactive.
- Ignition ON, doors closed, verify the scan tool All Door Lock Command is On.
- Verify that the Key In Ignition Cylinder Switch parameter is YES when the key is in the ignition and NO when the key is out of the ignition.
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ignition switch. |
- If all circuits test normal, test or replace the IPC.
Repair Instructions
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.