Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the system operation and perform the necessary inspections? | -- | Go to Symptoms - Doors | |
2 |
Does the express down function operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | |
3 |
Does the test lamp illuminate? | -- | ||
4 | Test for and repair an open in circuit 164 between the power window control module terminal A and splice S263. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and repair an open? | -- | ||
5 | Repair the open in circuit 341 between the power window control module and splice S208. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
6 | Test for and repair a poor connection at the power window control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and repair a poor connection? | -- | ||
7 | Replace the power window control module. Did you complete the replacement? | -- | -- | |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK |