Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Do the stop lamps remain off? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Disconnect the stop lamp/tcc switch. Do the stop lamps turn off? | -- | Go to Step 4 | Go to Step 5 |
4 | Replace the stop lamp/tcc switch. Refer to Stop Lamp Switch Replacement in Hydraulic Brakes. Did you complete the replacement? | -- | Go to Step 6 | -- |
5 | Repair a short to battery voltage in the supply voltage circuit of the stop lamp. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |