Removal Procedure
- Remove the instrument
panel (IP) carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gauges and Console.
- Remove the front floor air duct. Refer to
Floor Air Outlet Replacement
.
- Remove the air distributor case face (1) and seal (2).
- Disconnect the vacuum hose from the defroster valve actuator.
- Disconnect the defroster valve actuator linkage from the defroster
actuator.
- Remove the defroster valve actuator (3).
Installation Procedure
- Install the defroster valve actuator
(3).
- Connect the defroster valve actuator linkage to the defroster
actuator.
- Connect the vacuum hose to the defroster valve actuator.
- Install the air distributor case face (1) and seal (2).
- Install the front floor air duct. Refer to
Floor Air Outlet Replacement
.
- Install the IP carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gauges
and Console.