Removal Procedure
- Remove the
instrument panel (IP) carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gauges and Console.
- Remove the front floor air duct. Refer to
Floor Air Outlet Replacement
.
- Remove the air distributor case face (1) and seal (2).
- Disconnect the mode valve actuator linkage from the mode valve.
- Remove the bi-level actuator (4) and linkage (3).
- Remove the bi-level mode actuator screw (5).
Installation Procedure
- Install the bi-level mode
actuator screw (5).
Tighten
Tighten the bi-level mode actuator screw to 2 N·m (18 lb in).
- Install the bi-level actuator (4) and linkage (3).
- Disconnect the mode valve actuator linkage from the mode valve.
- Install the air distributor case face (1) and seal (2).
- Install the front floor air duct. Refer to
Floor Air Outlet Replacement
.
- Install the IP carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gauges and Console.