Removal Procedure
- Remove the heating, ventilation and air conditioning
(HVAC) control. Refer to
Control Assembly Replacement
.
- Remove the HVAC control selector switch screws (2, 4).
- Remove the HVAC control vacuum valve (3) from the selector switch
(5).
Installation Procedure
- Install the HVAC control vacuum valve (3) to
the selector switch (5).
- Install the HVAC control selector switch screws (2, 4).
Tighten
Tighten the HVAC control selector switch screws to 2 N·m
(18 lb in).
- Install the HVAC control. Refer to
Control Assembly Replacement
.