- Remove the right instrument
panel (IP) insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gauges and Console.
- Remove the temperature control cable bolt.
- Disconnect the temperature control cable at the air conditioning
(A/C) module.
Important: Ensure that the temperature control cable (3) is still attached to the
heating, ventilation and air conditioning (HVAC) control.
- Cycle the temperature control knob between the following positions:
- Replace the temperature control cable if one of the following
situations occur:
• | The temperature control cable binds |
• | The temperature control cable does not rotate freely |
- Set the temperature control knob to the detent position half way
between the full cold and the full hot positions.
- Inspect the position of the temperature control cable pulley (2).
Adjust the temperature control cable pulley (2):
• | Do not adjust the pulley if the pulley is skewed 5-10 degrees
toward the full cold side. |
• | Adjust the control cable if the pulley is skewed toward the full
hot side. |
- Remove the spring (4) from the temperature control cable pulley.
- Adjust the temperature control cable pulley 5-10 degrees
toward the full cold position.
- Install the temperature
control cable spring (4) to the temperature control cable pulley (2).
- Connect the temperature control cable (5) to the heater module.
- Connect the temperature
control cable to the A/C module.
- Install the temperature control cable bolt.
Tighten
Tighten the temperature control cable bolt to 1.9 N·m (17 lb in).
- Install the right IP insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gauges and Console.