Removal Procedure
- Remove the key from the
ignition switch in order to ensure that the ignition switch will remain OFF.
- Remove the right instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gauges and Console.
- Disconnect the blower motor electrical connector.
- Remove the blower motor bolts (2).
- Remove the blower motor (3).
- Inspect the blower motor terminals for corrosion.
Perform the following tasks as necessary:
• | Clean the corrosion from the terminals. |
• | Replace the blower motor. |
- Inspect the flange of the blower motor for any damage or distortion
which could cause an air leak.
Repair the flange of the blower motor as necessary.
- Inspect the blower motor fan for damage and distortion.
Perform the following tasks as necessary:
• | Repair the blower motor fan. |
• | Replace the blower motor fan. |
Installation Procedure
- Install the blower motor
(3) using the following steps:
1.1. | Guide the blower motor (3) into position. |
Do not catch the blower motor fan on the protruding parts.
1.2. | Install the blower motor bolts (2). |
Tighten
Tighten the blower motor bolts (2) to 2.3 N·m (20 lb in).
- Connect the blower motor electrical connector.
- Install the right instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gauges and Console.
- Check the blower for proper operation.