Removal Procedure
- Remove the key from the
ignition in order to assure that the ignition switch will remain in the OFF
position.
- Remove the right instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gauges and Console.
- Pull the carpet away from the heater module.
- Remove the blower motor resistor bolt (2).
- Disconnect the blower motor resistor electical connector.
- Remove the blower motor resistor (1).
Installation Procedure
- Install the blower motor
resistor (1).
- Connect the blower motor resistor electical connector.
- Install the blower motor resistor bolt (2).
Tighten
Tighten the blower motor resistor bolt to 2 N·m
(18 lb in).
- Reposition the carpet.
- Install the right instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gauges and Console.
- Test the blower motor operation at each of the four speeds.