Thermostat Testing Procedure
Check the operation of the thermostat by hanging
the thermostat on a hook in a 33% glycol solution.
In order to check if the thermostat valve is opening properly, do the
following test:
- Completely submerge the thermostat in a glycol solution. The solution
should be 11°C (22°F) above the temperature indicated on the thermostat
valve.
- Thoroughly agitate the solution. Under these conditions, the thermostat
valve should open.
In order to check if the thermostat valve is closing properly, do the
following test:
- Completely submerge the thermostat in a glycol solution. The solution
should be 6°C (10°F) below the temperature indicated on the thermostat
valve.
- Thoroughly agitate the solution. Under these conditions, the thermostat
valve should close completely.