Table 1: | Dash Integration Module (DIM) Scan Tool Data List |
Table 2: | Instrument Panel Module (IPM) Scan Tool Data List |
Table 3: | PCM Scan Tool Data List |
Use the Scan Tool Data Display Values and Definitions Information in order to assist in diagnosing the Instrument Panel Integration Module (IPM) problems. Compare the vehicles actual scan tool data with the typical data display value table information. Use the data information in order to aid in understanding the nature of the problem when the vehicle does not match with the typical data display values.
The scan tool data values were taken from a known good vehicle under the following conditions:
• | The ignition switch is in the ON position. |
• | The engine is running at idle. |
• | The vehicle is in PARK. |
• | The doors are closed. |
• | The windows are closed. |
• | The A/C is ON. |
• | The ambient air temperatures are at 22-27°C (70-80°F). |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
A/C Clutch (actual) | A/C Information | On/Off | On |
A/C Clutch (desired) | A/C Information | On/Off | On |
A/C Pressure | A/C Information | kPa/psi | 1337 kPa (194 psi) |
Clutch Voltage | A/C Information | Low/Normal | Normal |
Control Head (desired) | A/C Information | On/Off | On |
Pressure Status | A/C Information | Low/High/Normal | Normal |
Steering Wheel Controls | Inputs | Counts | 0 |
Temperature Status | A/C Information | Low/High/OK | OK |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
8 Digit GM Part Number | Module Information | 8 digit alphanumeric | 19632398 |
A/C Requested | HVAC System Data | Yes/No | Yes |
Air Inlet Dr Actual | HVAC Door Positions | Counts/Volts | 34-206 Counts (0.67-4.04 Volts) |
Air Inlet Dr Commanded | HVAC Door Positions | Counts/Volts | 35-206 Counts (0.69-4.04 Volts) |
Calibration ID | Module Information | 8 digit numeric | 09388017 |
Commanded Blower | HVAC System Data | Percentage | 10-100% |
Component Serial Number | Module Information | 4 digit numeric | 3958 |
Coolant Temperature | HVAC System Data | °C/°F | 91°C (195°F) |
Htr./Def./A/C Dr Actual | HVAC Door Positions | Counts/Volts | 18-235 Counts/0.35-4.61 Volts |
Htr./Def./A/C Dr Commanded | HVAC Door Positions | Counts/Volts | 18-235 Counts/0.35-4.61 Volts |
Inside Air Temp | HVAC Sensors | °C/°F | 20°C (69°F) |
Inside Air Temp | Open/Short Data | Counts/Volts | 119 Counts/2.33 Volts |
Julian Date of Build | Module Information | 3 digit numeric | varies |
Left AC Duct Temp | HVAC Sensors | °C/°F | 20°C (68°F) |
Left AC Duct Temp | Open/Short Data | Counts/Volts | 146 Counts/2.86 Volts |
Left Duct Temp Desired | HVAC Sensors | °C/°F | 20°C/69°F |
Left Htr. Duct Temp | HVAC Sensors | °C/°F | 30°C (86°F) |
Left Htr. Duct Temp | Open/Short Data | Counts/Volts | 107 Counts/2.10 Volts |
Left Program Number | HVAC System Data | Counts | 12-243 Counts |
Left Solar | HVAC Sensors | Counts | 227 Counts |
Left Solar Sensor | Open/Short Data | Counts/Volts | 227 Counts/4.45 Volts |
Left Temp Dr Actual | HVAC Door Positions | Counts/Volts | 36-214 Counts/0.71-4.19 Volts |
Left Temp. Dr. Commanded | HVAC Door Positions | Counts/Volts | 36-214 Counts/0.71-4.19 Volts |
Load Reduction Active | HVAC System Data | Yes/No | No |
Max Air Inlet Dr Pos | HVAC Door Calibrations | Counts/Volts | 206 Counts/4.04 Volts |
Max Htr./Def./A/C Dr. Pos. | HVAC Door Calibrations | Counts/Volts | 235 Counts/4.61 Volts |
Max Left Temp Dr Pos | HVAC Door Calibrations | Counts/Volts | 214 Counts/4.19 Volts |
Max Right Temp Dr Pos | HVAC Door Calibrations | Counts/Volts | 214 Counts/4.19 Volts |
Min Air Inlet Dr Pos | HVAC Door Calibrations | Counts/Volts | 36 Counts/0.71 Volts |
Min. Htr./Def./A/C Dr. Pos. | HVAC Door Calibrations | Counts/Volts | 18 Counts/.35 Volts |
Min Left Temp Dr Pos | HVAC Door Calibrations | Counts/Volts | 36 Counts/0.71 Volts |
Min Right Temp Dr Pos | HVAC Door Calibrations | Counts/Volts | 49 Counts/0.96 Volts |
Outside Air Temp | HVAC Sensors | °C/°F | 24°C (75°F) |
Outside Air Temp | Open/Short Data | Counts/Volts | 82 Counts/1.61 Volts |
PROM ID | Module Information | 8 digit alphanumeric | AE010015 |
Right AC Duct Temp | HVAC Sensors | °C/°F | 17°C/62°F |
Right AC Duct Temp | Open/Short Data | Counts/Volts | 125 Counts/2.45 Volts |
Right Duct Temp Desired | HVAC Sensors | °C/°F | 20°C/69°F |
Right Htr. Duct Temp | HVAC Sensors | °C/°F | 37°C/100°F |
Right Htr. Duct Temp | Open/Short Data | Counts/Volts | 81 Counts/1.59 Volts |
Right Program Number | HVAC System Data | Counts | 12-243 Counts |
Right Solar | HVAC Sensors | Counts | 228 Counts |
Right Solar Sensor | Open/Short Data | Counts/Volts | 228 Counts/4.47 Volts |
Right Temp Dr Actual | HVAC Door Positions | Counts/Volts | 49-214 Counts/0.96-4.19 Volts |
Right Temp. Dr. Commanded | HVAC Door Positions | Counts/Volts | 49-214 Counts/0.96-4.19 Volts |
Selected Air Mode | HVAC System Data | Defrost Defog Upper Bi-Level Heater Auto | varies |
System Program Number | HVAC System Data | Counts | 12-243 Counts |
Vehicle Speed | HVAC System Data | km/h/mph | 0 km/h/0 mph |
Year Module Built | Module Information | 4 digit numeric | 1999 |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
A/C High Side Pressure | Engine Data 2 | kPa/psi | 965 kPa/140 psi |
A/C High Side Pressure | Engine Data 2 | Volts | 1.65 Volts |
A/C Off For WOT | Engine Data 2 | Yes/No | No |
A/C Pressure Disable | Engine Data 2 | Yes/No | No |
A/C Relay Circuit Status | Output Driver Data | OK/Fault | OK |
A/C Relay Command | Engine Data 1 Engine Data 2 EGR Data Misfire Data | On/Off | On |