Removal Procedure
- Disconnect the AIR inlet hose from the air box
upper cover.
- Disengage the air cleaner cover latches.
- Gently pull upward to remove the air resonator (3) and element
cover from the air cleaner housing.
- Disconnect the mass air flow (MAF)/intake air temperature (IAT) sensor
electrical connector (1).
- Remove the air cleaner element.
- Remove any loose debris that may be found laying in the base of the air
cleaner.
Installation Procedure
- Install the new air filter element.
- Reconnect the MAF/IAT sensor electrical connector (1).
- Install the air resonator (3) and element cover to the air cleaner
housing.
- Snap both latches into place.
- Connect the AIR inlet hose to the air box upper
cover.