Removal Procedure
Important:
• | Always use replacement cables that are of the same type, diameter and
length of the cables that you are replacing. |
• | Always route the replacement cable the same way as the original cable. |
- Remove the push in retainers (2) securing the
upper filler panel (1) to the vehicle.
- Remove the upper filler panel (1) from the vehicle.
- Remove
the bolt (1) securing the engine ground cable (2) to the right side
body frame rail.
- Remove the bolt securing the engine ground cable to the generator.
- Remove the engine ground cable from the vehicle.
Installation Procedure
- Position the engine ground cable to the engine.
Notice: Refer to Fastener Notice in the Preface section.
- Install the bolt securing the engine ground cable to the generator.
Tighten
Tighten the generator mounting bolt to 50 N·m (37 lb ft).
- Install
the bolt (1) securing the engine ground cable (2) to the right side
body frame rail.
Tighten
Tighten the engine ground cable bolt to 50 N·m (37 lb ft).
- Install the upper filler panel (1) to the vehicle.
- Install the push in retainers (2) in order to secure the upper filler
panel (1) to the vehicle.
- Close the hood.