Table 1: Climate Control Panel (CCP) Scan Tool Data List
Table 2: Dash Integration Module (DIM) Scan Tool Data List
Table 3: PCM Scan Tool Data List

Use the Scan Tool Data Display Values and Definitions Information in order to assist in diagnosing the Instrument Panel Integration Module (IPM) problems. Compare the vehicles actual scan tool data with the typical data display value table information. Use the data information in order to aid in understanding the nature of the problem when the vehicle does not match with the typical data display values.

The scan tool data values were taken from a known good vehicle under the following conditions:

    • The ignition switch is in the ON position.
    • The engine is running at idle.
    • The vehicle is in PARK.
    • The doors are closed.
    • The windows are closed.
    • The A/C is ON.
    • The ambient air temperatures are at 22-27°C (70-80°F).

Climate Control Panel (CCP) Scan Tool Data List

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)

8 Digit GM Part Number

Module Information 2

8 digit alphanumeric

09383334

Air Inlet Dr Commanded

HVAC System Data

Percentage

0-87%

Calibration ID

Module Information 1

4 digit numeric

9912

Commanded Blower

HVAC System Data

Percentage

7-99%

Component Serial No. 8-11

Module Information 2

4 digit numeric

varies

Component Serial No. 12

Module Information 2

1 digit numeric

varies

Component Serial No. 13-16

Module Information 2

4 digit numeric

varies

Component Serial No. 17-18

Module Information 2

2 digit numeric

varies

Htr./Def./A/C Dr Commanded

HVAC System Data

Percentage

2-100%

Julian Date of Build

Module Information

3 digit numeric

varies

PROM ID

Module Information

4 digit alphanumeric

9811

Temp Dr. Commanded

HVAC System Data

Percentage

33-98%

Year Module Built

Module Information 1

4 digit numeric

2000

Dash Integration Module (DIM) Scan Tool Data List

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)

A/C Clutch (actual)

A/C Information

On/Off

On

A/C Clutch (desired)

A/C Information

On/Off

On

A/C Pressure

A/C Information

kPa/psi

965 kPa/140 psi

Clutch Voltage

A/C Information

Low/Normal

Normal

Control Head (desired)

A/C Information

A/C On/A/C Off

A/C On

Pressure Status

A/C Information

Low/High/Normal

Normal

Temperature Status

A/C Information

Low/High/OK

OK

PCM Scan Tool Data List

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)

A/C High Side Pressure

Engine Data 2

kPa/psi

965 kPa/140 psi

A/C High Side Pressure

Engine Data 2

Volts

1.65 Volts

A/C Off For WOT

Engine Data 2

Yes/No

No

A/C Pressure Disable

Engine Data 2

Yes/No

No

A/C Relay Circuit Status

Output Driver Data

OK/Fault

OK

A/C Relay Command

EGR Data

Engine Data 1

Engine Data 2

Misfire Data

On/Off

On