The switch that failed and generated this diagnostic trouble code (DTC) is wired to either the driver door switch assembly (DDSA) or the passenger door module (PDM). The DDSA or the PDM includes the switch state in the power door serial data message it sends to the driver door module (DDM). The DDM sends the switch message to the rear integration module (RIM), which is the master of all lock operations, as a Class 2 message. The RIM checks all conditions and if all conditions are correct, sends its OK back to the DDM. When the OK message is received, the DDM sends the required signal to all other door modules via the power door serial data message system.
The DDSA, DDM, and PDM must be powered, in communications with each other and can not have B1327-Battery Voltage Low or B1328-Battery Voltage High set for these DTCs to set.
If the DDM receives the message that either a passenger door lock switch circuit is closed for more than 30 continuous seconds or a DDSA lock switch circuit is closed for more than 255 seconds (4.25 minutes), the DDM sets a lock switch circuit DTC.
The DDM ignores any message from the lock switch designated by the DTC and prevents lock movement from the switch. The DDM will respond to other lock switch messages.
The DDM clears this current DTC when the switch message is no longer received and stores a history DTC. The history DTC will clear either after 50 OFF/ON ignition switch cycles without a repeated failure or in response to a scan tool command.
The number(s) below refer to the step number(s) on the diagnostic table.
Check the module input state using the normal input status.
Check to see that the input is seen by the module.
Check to see that the signal lines to the module are open with the switch removed.
Determine that the signal circuits are not shorted.
Step | Action | Yes | No |
---|---|---|---|
Schematic References: Door Lock/Indicator Schematics and Door Control Module Schematics | |||
1 | Did you perform the Door Systems Diagnostic System Check? | Go to Step 2 | |
Does the scan tool display Idle? | Go to Step 3 | Go to Step 4 | |
Does the door lock switch parameter change state? | Go to Testing for Electrical Intermittents in Wiring Systems | Go to Step 4 | |
Does the scan tool display Idle? | Go to Step 7 | Go to Step 5 | |
Test the signal circuits of the appropriate door lock switch for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 6 | |
6 | Inspect for poor connections at the harness connector of the appropriate door control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 8 |
7 | Inspect for poor connections at the harness connector of the appropriate door lock switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 9 |
8 | Replace the appropriate door control module. Refer to Door Control Module Replacement . Did you complete the replacement? | Go to Step 10 | -- |
9 | Replace the appropriate door lock switch. Refer to Door Lock Switch Replacement . Did you complete the replacement? | Go to Step 10 | -- |
10 |
Does the DTC reset? | Go to Step 2 | System OK |