Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Power Window Schematics | |||
1 | Did you review the power windows operation and perform the necessary inspections? | Go to Step 2 | Go to Symptoms - Doors |
2 | Verify the fault is present. Does the system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 5 |
4 | Repair the short to voltage in the power window master switch lockout signal circuit. Refer to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 6 | Go to Step 5 |
5 | Replace the LF side door window switch. Refer to Front Side Door Window Switch Replacement - Left Side . Did you complete the replacement? | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |