Removal Procedure
- Remove the knee bolster. Refer to
Knee Bolster Replacement
in Instrument Panel, Gages and Console.
Important: The HVAC controls must be set to the vent mode to position the defroster door lever for access to the air temperature actuator.
- Set the HVAC controls to the vent mode to position the defroster door lever.
- Remove the left hand temperature door lever bolt (3) from the HVAC module.
- Disconnect and remove the left hand temperature door lever spring (2).
- Disconnect and remove the LH temperature door lever (1) from the LH temperature door.
- Disconnect the left hand air temperature actuator electrical connector.
- Remove the left hand air temperature actuator mounting screws.
- Remove the left hand air temperature actuator.
Installation Procedure
- Install the left hand air temperature actuator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the left hand air temperature actuator mounting screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Connect the left hand air temperature actuator electrical connector.
Important: Align the pin on the left hand air temperature actuator with the slot in the left hand temperature door lever.
- Install the left hand temperature door lever (1) to the left hand temperature door.
- Connect the left hand temperature door lever spring (2) to the left hand temperature door lever (1) and HVAC module case.
- Install the left hand temperature door lever bolt (3) to the HVAC module case.
Tighten
Tighten the bolt to 0.9 N·m (8 lb in).
- Install the knee bolster. Refer to
Knee Bolster Replacement
in Instrument Panel, Gages and Console.