GM Service Manual Online
For 1990-2009 cars only

Tools Required

J 39400-A Halogen Leak Detector

Removal Procedure

  1. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging .
  2. Raise and support the vehicle. Refer to Lifting and Jacking the Vehicle in General Information.

  3. Object Number: 125807  Size: SH
  4. Remove the air baffle bolts.
  5. Remove the air baffle.

  6. Object Number: 718244  Size: SH
  7. Loosen the A/C refrigerant filter flare nuts.
  8. Important: Immediately cap or tape the open evaporator inlet tubes in order to prevent contamination.

  9. Remove the A/C refrigerant filter from the evaporator tube.
  10. Discard the O-rings.

Installation Procedure

  1. Remove the cap or the tape from the evaporator inlet tubes.

  2. Object Number: 718244  Size: SH
  3. Lubricate and install new O-rings to each end of the evaporator tube. Refer to O-Ring Replacement .
  4. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

    Important: Fully seat the A/C filter to the ferrules in order to ensure that the O-rings seat inside the filter housing.

  5. Install the A/C refrigerant filter to the evaporator inlet tube with the arrow pointing toward the evaporator.
  6. Tighten
    Tighten the flare nuts to 15 N·m (11 lb ft).


    Object Number: 125807  Size: SH
  7. Install the air baffle.
  8. Install the air baffle bolts.
  9. Tighten
    Tighten the bolts to 20 N·m (15 lb ft).

  10. Lower the vehicle.
  11. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging .
  12. Leak test the fittings of the component using J 39400-A .