Step

Action

Yes

No

1

Did you review the ALC System Description and Operation and perform the necessary inspections?

Go to Step 2

Go To Symptoms - Automatic Level Control

2

Verify the condition is present.

Does the system operate normally?

Go to Testing for Intermittent Conditions and Poor Connections

Go to Step 3

3

Turn ON the ignition, with the engine OFF.

Place the inflator switch in the ON position.

Does the automatic level control compressor motor run with NO air at inflator valve?

Go to Step 15

Go to Step 4

4

Disconnect the automatic level control inflator air switch connector.

Connect a fused jumper wire between the automatic level control inflator relay coil control circuit and ground.

Does the automatic level control compressor motor run?

Go to Step 5

Go to Step 6

5

Replace automatic level control inflator air switch.

Refer to Automatic Level Control Inflator Air Switch Replacement

Did you complete the replacement?

Go to Step 19

--

6

Test the ground circuit of the automatic level control inflator air switch for an open.

Did you find and correct the condition?

Go to Step 19

Go to Step 7

7

Disconnect the automatic level control inflator time relay.

Connect a fused jumper wire between the automatic level control relay control supply voltage and ground.

Does the automatic level control compressor motor run?

Go to Step 8

Go to Step 10

8

Inspect for poor connections at the harrness connector of the automatic level control inflator time relay.

Did you find and correct the condition?

Go to Step 19

Go to Step 9

9

Replace automatic level control time relay.

Did you complete the replacement?

Go to Step 19

--

10

Disconnect the automatic level control compressor connector.

Connect a test lamp between the automatic level control compressor motor supply voltage circuit and ground.

Does the test lamp illuminate?

Go to Step 11

Go to Step 13

11

Inspect for poor connections at the harrness connector of the automatic level control compressor assembly.

Did you find and correct the condition?

Go to Step 19

Go to Step 12

12

Relace automatic level control compressor.

Did you complete the replacement?

Go to Step 19

--

13

Inspect for poor connections at the harrness connector of the automatic level control compressor relay.

Did you find and correct the condition?

Go to Step 19

Go to Step 14

14

Replace the automatic level control compressor relay.

Did you complete the replacement?

Go to Step 19

--

15

Disconnect the automatic level control solenoid valve connector.

Connect a test lamp between the automatic level control solenoid valve supply voltage and ground.

Place the inflator switch in the ON position.

Does the test lamp illuminate?

Go to Step 16

Go to Step 17

16

Inspect for poor connections at the harrness connector of the automatic level control compressor relay.

Did you find and correct the condition?

Go to Step 19

Go to Step 18

17

Inspect for poor connections at the harrness connector of the automatic level control compressor relay.

Did you find and correct the condition?

Go to Step 19

Go to Step 9

18

Replace automatic level control solenoid valve.

Refer to Inflator Solenoid Replacement

Did you complete the replacement?

Go to Step 19

--

19

Operate the system in order to verify the repair.

Did you correct the condition?

System OK

Go to Step 1