• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
A/C Compressor Clutch Relay Control | P0645 | P0645 | P0645 | -- |
A/C Relay Coil Side Supply Voltage | -- | P0645 | -- | -- |
Ignition voltage is supplied directly to the A/C compressor clutch relay. The engine control module (ECM) controls the relay by grounding the A/C clutch relay control circuit.
• | The ignition voltage is between 11.0-18.0 volts. |
• | The engine speed is less than 600 RPM. |
• | The A/C is commanded from ON to OFF or from OFF to ON. |
The ECM detects an open on the control circuit of the A/C compressor clutch relay when commanded off with the engine in crank or run status.
The ECM will store conditions which were present when the DTC set as failure records data only. This information will not be stored as freeze frame data.
A history DTC clears after 40 consecutive warm-up cycles have occurred without a malfunction.
Control Module References for scan tool information
Ignition ON, with the engine OFF, command the A/C Relay ON and OFF with a scan tool. Feel/listen for the A/C relay to click.
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the resistance is not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |