The power sliding door (PSD) is operated through 3 switches installed on the vehicle, and via the keyless entry transmitter.
The interior lamp and the multifunction switch located in the overhead console contain the following components:
• | The PSD on/off switch |
• | The PSD open/close switch |
The PSD on/off switch enables (ON position) or disables (OFF position) the PSD operation.
When the PSD on/off switch is set to the ON position, the PSD on/off switch sends a ground signal to the rear side door actuator control module. The ground signal is sent through CKT 1896. This action enables the PSD operation. When the PSD on/off switch is set to the OFF position, CKT 1896 is no longer grounded. This action disables the PSD operation.
A ground signal is sent to the rear side door actuator control module through CKT 1894 when either of the following components are pressed:
• | The PSD open/close switch located in the overhead console |
• | The PSD open/close switch (RH B-pillar) |
This action causes the PSD to either open or close if all of the following conditions exist:
• | The PSD on/off switch is set to the ON position. |
• | The sliding door lock is unlocked. |
• | The transaxle is in the PARK position (for PSD open commands only). |
• | No Diagnostic Trouble Codes (DTCs) are present. |
The PSD open/close switch (RH B-pillar) works in the same matter as the PSD switch located in the overhead console.
The following components receive their ground through CKT 650.
• | The PSD on/off switch |
• | The PSD open/close switch located in the overhead console |
• | The PSD open/close switch (RH B-pillar) |
• | Inspect the PSD for the following conditions: |
- | A faulty PSD on/off switch |
- | A faulty PSD open/close switch (overhead console) |
- | A faulty PSD open/close switch (RH B-pillar) |
- | A short to the ground in CKT 1894 |
- | An open in CKT 1894 |
- | A malfunction in the keyless entry system |
• | An intermittent failure may be very difficult to detect and to diagnose accurately. Faulty electrical connections or wiring causes most intermittent problems. When an intermittent condition is suspected, check the suspected circuits for the following conditions: |
• | Poor mating of connector halves or backed out terminals |
• | Improperly formed or damaged terminals |
• | Wire chafing |
• | Poor wire to terminal connections |
• | Dirty or corroded terminals |
• | Damage to connector bodies |
• | Wire broken inside the insulation |
• | Use a J 35616 whenever a diagnostic procedure requests probing or inspecting of a terminal. In order to ensure no damage will occur to the terminal use the J 35616 . This tool will give you an idea of how much terminal tension contact is sufficient. |
The number(s) below refer to the step number(s) on the diagnostic table.
This step performs Diagnostic Mode 2: Input Test.
This step tests for an open in CKT 650.
This step tests for a faulty PSD ON/OFF switch.
This step tests for a faulty PSD OPEN/CLOSE switch in the overhead console.
This step tests for a short to ground in CKT 1896.
This step tests for a short to B+ in CKT 1896.
This step tests for an open in CKT 1896.
This step tests for a short to ground in CKT 1894.
This step tests for a faulty PSD OPEN/CLOSE switch (right B-pillar) where the contacts are closed at all times.
This step tests for a faulty Remote Control Door Lock Receiver (RCDLR).
This step tests for an open in CKT 1894.
Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Perform the PSD Diagnostic System Check. Refer to Power Sliding Door (PSD) Diagnostic System Check . Was the PSD Diagnostic System Check performed? | -- | Go to Step 2 | |||||
2 | Enter the Diagnostic Mode 2: Input Test. Refer to Diagnostic Modes in Power Sliding Door (PSD) Diagnostic Information . During Diagnostic Mode 2, the PSD alarm toggles between ON and OFF when the following conditions exist:
Does the PSD alarm sound as described above? | -- | Go to Step 23 | Go to Step 3 | ||||
3 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 13 | ||||
4 |
Does the resistance measure in the specified range? | On: Less than 2 ohms Off: Infinite | Go to Step 5 | Go to Step 14 | ||||
5 |
Does the resistance measure in the specified range? | Pressed: Less than 2 ohms Released: Infinite | Go to Step 6 | Go to Step 14 | ||||
6 |
Does the resistance measure in the specified range? | Infinite | Go to Step 7 | Go to Step 15 | ||||
7 |
Does the voltage measure in the specified range? | Less than 2 V | Go to Step 8 | Go to Step 16 | ||||
8 | Using a J 39200 DMM, measure the resistance between the rear side door actuator control module harness connector C2 terminal 13 and the interior lamp and multi-function switch harness connector C3 terminal D. Does the resistance measure in the specified range? | Less than 2 ohms | Go to Step 9 | Go to Step 17 | ||||
9 |
Does the resistance measure near the specified range? | Infinite | Go to Step 11 | Go to Step 10 | ||||
10 |
Does the resistance measure near the specified range? | Infinite | Got to Step 18 | Go to Step 19 | ||||
11 |
Does the resistance measure near the specified range? | Infinite | Go to Step 12 | Go to Step 20 | ||||
12 | Using a J 39200 DMM, measure the resistance between the rear side door actuator control module harness connector C2 terminal 10 and the interior lamp and multi-function switch harness connector C3 terminal C. Does the resistance measure in the specified range? | Less than 10 ohms | Go to Step 21 | Go to Step 22 | ||||
13 | Repair the poor connection or open in CKT 650. Refer to Wiring Repairs in Wiring. Is the repair complete? | -- | Go to Step 23 | -- | ||||
14 | Replace the interior lamp and multi-function switch. Refer to Multifunction Switch Assembly Replacement - Instrument Panel in Lighting Systems. Is the repair complete? | -- | Go to Step 23 | -- | ||||
15 | Repair the short to ground in CKT 1896. Refer to Wiring Repairs in Wiring. Is the repair complete? | -- | Go to Step 23 | -- | ||||
16 | Repair the short to B+ in CKT 1896. Refer to Wiring Repairs in Wiring. Is the repair complete? | -- | Go to Step 23 | -- | ||||
17 | Repair the poor connection or open in CKT 1896. Refer to Wiring Repairs in Wiring. Is the repair complete? | -- | Go to Step 23 | -- | ||||
18 | Replace the PSD open/close switch (right B-pillar). Refer to Power Sliding Door (PSD) Open/Close Pillar Switch Replacement . Is the repair complete? | -- | Go to Step 23 | -- | ||||
19 | Repair the short to ground in CKT 1894. Refer to Wiring Repairs in Wiring. Is the repair complete? | -- | Go to Step 23 | -- | ||||
20 | Replace the RCDLR. Refer to Receiver Replacement in Keyless Entry System. Is the repair complete? | -- | Go to Step 23 | -- | ||||
21 |
Is the repair complete? | -- | Go to Step 23 | -- | ||||
22 | Repair the poor connection or open in CKT 1894. Refer to Wiring Repairs in Wiring. Is the repair complete? | -- | Go to Step 23 | -- | ||||
23 | A malfunction is not present at this time. Refer to Diagnostic Aids for information on intermittent failures. Is the action complete? | -- | Go to Step 24 | -- | ||||
24 |
Does the PSD operate normally? | -- | System OK |