Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Inspect the DRL fuse. Is the fuse open? | -- | Go to Step 2 | Go to Step 3 | ||||
2 | Repair a short to ground in CKT 1839. Is the repair complete? | -- | -- | |||||
3 | Inspect the HVAC/DRL fuse. Is the fuse open? | -- | Go to Step 4 | Go to Step 5 | ||||
4 | Repair a short to ground in CKT 241. Is the repair complete? | -- | -- | |||||
5 | Check for any diagnostic trouble codes (DTCs). Are there any DTCs present? | -- | Go to Diagnostic System Check - Body Control System in Body Control System | Go to Step 6 | ||||
6 |
Do the front turn signal lamps light? | -- | Go to Step 18 | Go to Step 7 | ||||
7 | Use a test lamp in order to backprobe between the DRL control module harness connector C2 terminal C and ground. Did the test lamp light? | -- | Go to Step 9 | Go to Step 8 | ||||
8 | Repair the following conditions in CKT 1839:
Is the repair complete? | -- | -- | |||||
9 | Use a test lamp in order to backprobe between the DRL control module harness connector C2 terminal F and ground. Did the test lamp light? | -- | Go to Step 11 | Go to Step 10 | ||||
10 | Repair the following conditions in CKT 241 between S264 and the DRL control module harness connector C2 terminal F:
Is the repair complete? | -- | -- | |||||
11 | Use a test lamp in order to backprobe between the DRL control module harness connector C2 terminal C and terminal A. Did the test lamp light? | -- | Go to Step 13 | Go to Step 12 | ||||
12 | Repair the following conditions in CKT 1450 between the DRL control module and G200:
Is the repair complete? | -- | -- | |||||
13 | Use a test lamp in order to backprobe between B+ and the DRL control module harness connector C2 terminal E. Did the test lamp light? | -- | Go to Step 14 | Go to Step 17 | ||||
14 |
Did the test lamp light? | -- | Go to Step 16 | Go to Step 15 | ||||
15 |
Is the repair complete? | -- | -- | |||||
16 |
Is the repair complete? | -- | -- | |||||
17 |
Is the repair complete? | -- | -- | |||||
18 | Cover the DRL ambient light sensor. Does the low beam headlamps and the park lamps turn on, and the turn signal lamps turn off? | -- | Go to Step 17 | Go to Step 19 | ||||
19 | Disconnect the DRL ambient light sensor. Do the low beam headlamps and park lamps turn on? | -- | Go to Step 21 | Go to Step 20 | ||||
20 | Use a J 39200 digital multimeter (DMM) in order to verify continuity in CKT 1137 between the DRL ambient light sensor harness connector terminal B and the DRL control module harness connector C2 terminal G. Is there continuity in CKT 1137? | -- | Go to Step 23 | Go to Step 22 | ||||
21 | Replace the DRL ambient light sensor. Refer to Daytime Running Lamp (DRL) Ambient Light Sensor Replacement . Is the repair complete? | -- | -- | |||||
22 | Repair the following conditions in CKT 1137:
Is the repair complete? | -- | -- | |||||
23 | Use a J 39200 DMM in order to verify continuity in CKT 1138 between the DRL ambient light senor harness connector terminal A and the DRL control module harness connector C2 terminal H. Is there continuity in CKT 1138? | -- | Go to Step 17 | Go to Step 24 | ||||
24 | Repair the following conditions in CKT 1138:
Is the repair complete? | -- | -- |