Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the entire HVAC System Check performed? | -- | Go to Step 2 | Go to HVAC System Check |
2 |
Is the test light on? | -- | Go to Step 3 | Go to Step 4 |
3 | Backprobe with a test light between the electric slave actuator connector terminal 7 and B+. Is the test light on? | -- | Go to Step 5 | Go to Step 6 |
4 | Repair the poor connection or open in CKT 241 between the electric slave actuator connector terminal 10 and S264. Is the repair complete? | -- | Go to Step 11 | -- |
5 |
Is the resistance within the specified values? | 0-2 ohms | Go to Step 7 | Go to Step 8 |
6 | Repair the poor connection or open in CKT 150 between the electric slave actuator connector terminal 7 and S213. Is the repair complete? | -- | Go to Step 11 | -- |
7 | Using a J 39200 , check for continuity in CKT 733 between the heater-A/C control connector C2 terminal G and ground. Is CKT 733 shorted to ground? | -- | Go to Step 9 | Go to Step 10 |
8 | Repair the poor connection or open in CKT 733 between the electric slave actuator connector terminal 8 and the heater-A/C control connector C2 terminal G. Is the repair complete? | -- | Go to Step 11 | -- |
9 | Repair the short to ground in CKT 733. Is the repair complete? | -- | Go to Step 11 | -- |
10 | Replace the electric slave actuator. Refer to Temperature Actuator Replacement . Is the repair complete? | -- | Go to Step 11 | -- |
11 |
Have all repairs been made? | -- | Go to HVAC System Check | -- |