Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the entire HVAC System Check performed? | -- | Go to Step 2 | Go to HVAC System Check |
2 |
Is the test light on? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the auxiliary blower motor resistor. Refer to Auxiliary Blower Motor Resistor Replacement . Is the repair complete? | -- | Go to Step 7 | -- |
4 | Backprobe with a test light between the rear window wiper/washer and multi-function switch connector C2 of the inoperative terminal (1=A, 2=C, 3=B) and B+. Is the test light on? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair the open in the inoperative circuit (1=1176, 2=1072, 3=1052). Is the repair complete? | -- | Go to Step 7 | -- |
6 | Replace the rear window wiper/washer and multi-function switch. Refer to Auxiliary Air Conditioning (A/C) Control Assembly Replacement - Front . Is the repair complete? | -- | Go to Step 7 | -- |
7 |
Have all repairs been made? | -- | Go to HVAC System Check | -- |