Condition
| Cause
| Action
|
The power sliding door (PSD) does not power unlatch/open
when the open/close switch is pressed. The door may power open if the door
is manually unlatched.
| The following conditions may prevent the unlatch actuator from activating:
• | CKT 750 and/or CKT 2910 is open. |
• | The unlatch actuator is defective. |
The following conditions may prevent the unlatch actuator and rod from
unlatching or opening the door:
• | The sliding door is locked. |
• | The front rod adjustment is too long. |
• | The unlatch actuator is defective. |
|
- Perform the Diagnostic Mode 3. Refer to Diagnostic Modes in
Power Sliding Door (PSD) Diagnostic Information
. Perform the indicated corrective action.
- Complete one of the following actions:
|
The following conditions exist:
• | The PSD unlatches but does not power open when you press the open/close
switch. |
• | The PSD does not power open if you move the door manually. |
| There is
an electrical malfunction within the PSD system.
| Refer to
Power Sliding Door (PSD) Diagnostic System Check
.
|
One of the following conditions exists:
• | The PSD unlatches but does not power open when you press the open/close
switch. The PSD power opens if you move the door manually. |
• | The PSD does not power open when you activate the handle. The
PSD power opens when you move the door manually. |
|
• | There is a malfunction in the detent switch circuit. |
• | The door lock rod is out of adjustment. |
• | An electric noise is present. |
|
• | Repair the electric noise: |
- | Verify that the pads and plungers are securely attached to the
body and the door. Replace the pouch fastener, as needed. |
- | Inspect for corrosion, water entry, and dirty or sticking plungers.
Clean or replace the plungers, as needed. |
- | Inspect the ground circuits. |
If these steps do not correct the condition, refer to
Power Sliding Door (PSD) Diagnostic System Check
.
|
The PSD reverses or
stops during a power opening.
|
• | There is a mechanical obstruction. |
• | The cable tension is incorrect. |
|
- Complete the following steps in order to clear the mechanical
obstruction, as needed:
• | Remove any foreign objects. Clean or replace the track, as needed. |
• | Inspect the roller brackets for binding. Adjust the lower track.
Use lithium grease in order to lubricate the lower track at the bend. |
• | Inspect the roller brackets for wear. Replace the brackets as
needed. |
- Adjust the cable tension. Refer to
Rear Side Door Actuator Cable Tension Adjustment
for regular
method or
Rear Side Door Actuator Cable Tension Adjustment
for atlernate method in Doors.
If these steps do not correct the condition, refer to
Power Sliding Door (PSD) Diagnostic System Check
.
|
The sliding door does
not remain open when the vehicle is on hill (incline or decline).
|
• | The cable tension is incorrect. |
• | The hold open system is faulty. |
|
• | Adjust, clean, or replace the hold open spring/retainer. |
If these steps do not correct the condition, refer to
Power Sliding Door (PSD) Diagnostic System Check
.
|