Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
Definition: The fasten-belts indicator lamp in the instrument panel does not turn on under the following conditions:
However the BCM sounds the reminder chime for 4-8 seconds. | ||||||||
1 |
Do the instrument cluster gages and indicators operate normally? | -- | Go to Step 2 | |||||
2 | Was the Body Control Module (BCM) System Check performed? | -- | Go to Step 3 | |||||
3 |
Is the fasten-belts indicator lamp on? | -- | Go to Step 7 | Go to Step 4 | ||||
4 |
Is the lamp filament open? | -- | Go to Step 8 | Go to Step 5 | ||||
5 | Using a J 39200 DMM, measure the resistance between the BCM harness connector C2 terminal D12 and the instrument cluster harness connector C2 terminal L. Is the resistance less than the specified value? | 2 ohms | Go to Step 6 | Go to Step 9 | ||||
6 | Using a test lamp, connect between B+ and the instrument cluster harness connector C2 terminal O. Is the test lamp illuminated? | -- | Go to Step 10 | Go to Step 11 | ||||
7 |
Is the repair complete? | -- | Go to Step 12 | -- | ||||
8 | Replace the fasten-belts indicator lamp bulb. Refer to Instrument Cluster Bulb Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- | Go to Step 12 | -- | ||||
9 | Repair poor connection or open in circuit 529. Is the repair complete? | -- | Go to Step 12 | -- | ||||
10 | The fasten-belts indicator lamp does not illuminate due to a malfunction in the instrument cluster. Refer to Instrument Cluster System Check in Instrument Panel, Gauges and Console for the diagnosis and repair of the instrument cluster. Is the repair complete? | -- | Go to Step 12 | -- | ||||
11 | Repair poor connection or open in circuit 1450. Is the repair complete? | -- | Go to Step 12 | -- | ||||
12 |
Are any BCM DTCs present? | -- | System OK |