Removal Procedure
- Remove the weather-strip (1)
from
the flange.
- Remove all traces of adhesive from around the perimeter of the
opening.
Installation Procedure
- Install the weather-strip (1)
to the flange.
- Inspect the weather-stripping (1) in order to verify that
the clinch is completely seated to the flange around the entire opening.
- Using a hose with no nozzle attached, test the weather-strip (1)
in order to verify that no leaks are present. If leaks are present, remove
the weather-strip.
- Brush Goodwrench Weather-strip Adhesive P/N 123145097,
3M 08011, or the equivalent around the perimeter of the flange.